Design · Installation · Commissioning · Maintenance

Liquid cooling for European AI data centers, from design to maintenance.

One partner accountable for the full loop, from the facility water to the racks, CDUs included.

The liquid cooling loop covered by CoreFlow Diagram of a liquid cooling loop. On the left, the facility water, an optional part of the scope. Inside the CoreFlow scope: the CDU, then the supply and return pipework with insulation, pre-assembled manifolds and sensors, down to the connection of each rack. COREFLOW SCOPE Facility water Primary loop, optional CDU in-row or demarcation Pipework, insulation, pre-assembled manifolds, sensors Rack connection, at each rack Supply Return

Who we are

A service team, not a product vendor.

CoreFlow is independent of cooling manufacturers. We work on your design or on one we build with you.

A leak or a fluid-quality issue means downtime and damaged GPUs, on racks worth several million dollars each. That is why a single team stays accountable from the first drawing to years of operation: we design or review the loop, supply and install it, flush, pressure-test and commission it, then monitor and maintain it.

  • Independent of cooling manufacturersWe select CDUs and components for your project, not for a catalogue.
  • The same written procedures from one site to the nextAcross Europe, every project follows the same methods and acceptance criteria.
  • One accountable team, not a chain of subcontractorsDesign, installation, commissioning and maintenance answer to the same people.

What we deliver

The whole chain, in 5 stages.

Entrust us with the full loop or with a single stage. Each stage ends with documents you can check.

Design

3D BIM model, CDU selection and redundancy, routing, sizing, instrumentation.

Supply and install

CDUs, stainless pipework, insulation, pre-assembled manifolds and sensors.

Commission

Flushing, disinfection, pressure testing, commissioning of the loop.

Hand over

Joint-by-joint traceability, test reports, as-built drawings.

Monitor, maintain

Monitoring of temperature, pressure, flow and leaks. Preventive maintenance, water analysis, on-call.

Our scope

The full loop between the facility water and the racks.

CDUs are part of our scope, supplied and installed. We can also take on the primary loop, so that you deal with a single counterpart.

Optional

Primary loop

The facility water side, on request.

CoreFlow scope

CDUs

In-row or at the demarcation point, supplied and installed.

Pipework and insulation

Stainless pipework, pre-assembled manifolds, sensors.

Rack connection

At each rack, ready for the hardware.

When to bring us in

As early as possible.

We plan backwards from your hardware delivery date, so the loop is ready when the racks arrive.

No liquid design yet

We design the loop in 3D BIM and deliver it end to end.

Design already fixed

We step in on execution alone, from installation to commissioning and handover.

Existing building

Extensions and air-to-liquid conversions, on a site that stays in operation.

Our commitments

What we commit to, with evidence.

Every commitment is backed by a record you receive at handover, not by a statement.

  • Leak-tightness of the loopProven by a recorded pressure test.
  • Conformity to the approved designChecked joint by joint.
  • Workmanship of pipework and valvesEvery joint traced.
  • Instrumentation and acceptance testsOn a pass or fail basis.
  • Water quality at handoverBacked by a dated analysis.

The team

The people who will work in your data hall.

Operations

9 years in cooling at a European hyperscaler, over 50 projects, including 3 direct liquid cooling deployments in 2025 and 2026.

Maintenance

Former cooling lead at a European hyperscaler, water treatment engineer since 2012.

Questions

In short.

What does CoreFlow do?

CoreFlow delivers liquid cooling for European data centers from design to maintenance. We design or review the loop in 3D BIM, supply and install the CDUs, pipework, insulation, pre-assembled manifolds and sensors, flush, pressure-test and commission the loop, then monitor and maintain it for the life of the system.

Which part of the cooling system does CoreFlow cover?

The full loop between the facility water and the racks, CDUs included. The primary loop is optional: we can take it on so that the client deals with a single counterpart.

Who does CoreFlow work for?

AI clouds and enterprise data centers, and cooling manufacturers who need a local second line for maintenance.

Planning a liquid-cooled deployment?

Tell us about your hardware delivery date and your site. We come back with a scope, a schedule and a price.